服装广告
 

产品分类

Switch Cabinet

Switch Cabinet

价格: 电议 元
卖家: 吴经理

咨询: 点击这里给我发消息

供货商:CHNSUN ELECTRIC MANUFACTURING CO.,LTD.
电 话:0760-89738123
传 真:0760-89738123
邮 箱:sales@cnsunpower.cn
地 址:No. 42, Jinxiu Road, Shangnan Industrial Zone, Fusha Town, Zhongshan City, Guangdong Province

以上为Switch Cabinet详细参数信息,Switch Cabinet图片由CHNSUN ELECTRIC MANUFACTURING CO.,LTD.提供,Switch Cabinet
  • 产品特性
KYN28-12 Switchgear

Product Description

Combined substation (hereinafter referred to as American box-type substation) puts the transformer body, high-voltage load switch, protection fuse and other equipment in the same sealed oil tank, so it is smaller in size. American box-type substation can be used both outdoors and indoors , widely used in industrial parks, residential areas, commercial centers, high-rise buildings and other places.

Product Features

  • The air insulation distance is large enough to avoid the possibility of accidents between phases.
  • The protection level of the shell is IP4X, which effectively prevents the human body and external solid objects from approaching live parts.
  • Protect personal safety and ensure reliable operation of equipment.
  • Key components of high-current equipment are made of non-magnetic materials to solve the temperature rise problem of high current.
  • Conditions of useService conditions

  • Ambient temperature: the highest temperature: +40℃, the lowest temperature: -15℃.
  • Environmental humidity Daily average relative humidity: ≤95%; Monthly average relative humidity: ≤90%
  • Altitude: no more than 1000m.
  • 技术参数Data Sheet

    serial number project unit Technical Parameters
    1 Rated voltage kV 3.6, 7.2, 12
    2 Short-term T frequency withstand voltage 1min kV 42
    3 Rated insulation level lightning impulse withstand voltage kV 75
    4 Rated frequency Hz 50
    5 Busbar rated current A 630, 1250, 1600, 2000
    2500, 3150, 4000
    6 Rated short-time withstand current (4S) k 20, 25, 31.5, 40, 50
    7 Rated peak withstand voltage k 50, 63, 80, 100, 125
    8 Rated short circuit making current k 50, 63, 80, 100, 125
    9 Protection level Shell IP4X (between compartments, IP2X when the circuit breaker door is open)
    GGDLV Complete Set Switchgear

    Product Features

  • Reasonable design: Carry out unit design based on the characteristics of various electrical switches and combine them into functional units.
  • Universal structure and flexible assembly: C-shaped profiles meet various structural forms.
  • Standard modules: Standard unit module structures such as protection, operation, conversion, and control can be composed into any combination.
  • Safety protection: The isolation between areas and the mutual isolation between the incoming and outgoing lines of functional units are used to effectively strengthen the safety protection performance.
  • Data Sheet

    serial number model Rated voltage (V) Rated current (A) Rated short circuit breaking current (KA) Rated short-time withstand current (KA/1s) Rated peak withstand current (KA)
    1 GGD1 380 A:1000
    B:600(630)
    C:400
    15 15 30
    2 GGD2 380 A:1500(1600)
    B:1000
    C:600
    30 30 63
    3 GGD3 380 A:3150
    B:2500
    C:2000
    50 50 105
    4 GGD4 380 A:4000
    B:3150
    C:2500
    80 80 176
    GCK LV Complete Set Switchgear

    Product FeaturesProduct Features

  • The design is compact and can accommodate more functional units in a smaller space.
  • The assembly is flexible and can meet the requirements of various structural forms, protection levels and usage environments.
  • Standard module design is purchased, and users can choose and assemble it according to their needs.
  • High safety, a large number of high-strength flame-retardant engineering plastic components are used to effectively enhance the protective safety performance.
  • Data Sheet

    serial number project unit data
    1 Main circuit rated voltage V Communication 380 (400), 660 (690)
    2 Auxiliary circuit rated voltage V AC 220, 380 (400); DC 110, 220
    3 Rated frequency Hz 50 (60)
    4 Rated insulation voltage V 660(1000)
    5 Rated current: horizontal bus A ≤4000
    6 Rated current: vertical busbar (MCC) A 1000
    7 Busbar rated short-time withstand current (1s) KA 50, 80
    8 Busbar rated peak withstand current (0.1s) V 105, 176
    9 Power frequency test voltage (1min): main circuit V 2500
    10 Power frequency test voltage (1min): auxiliary circuit V 1760
    11 Busbar: three-phase four-wire system A, B, C, PE, N
    12 Three-phase five-wire system A, B, C, PE, N
    13 Protection level IP40